Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Rev. bras. oftalmol ; 79(5): 336-339, set.-out. 2020. tab, graf
Article in English | LILACS | ID: biblio-1137986

ABSTRACT

Abstract Sclerochoroidal calcifications (SC) are a rare and benign ocular condition characterized by yellow-white irregular subretinal lesions usually found in the supero-temporal arcade of the midperipheral fundus in middle-aged elderly men. We present a clinical case of a 79- year-old patient who during a fundus examination presented raised whitish nodules in the supero-temporal arcade in the right eye. After performing optical coherence tomography, ultrasound, ocular computed tomography and laboratory analysis, she was diagnosed with idiopathic sclerochoroidal calcifications The pathogenesis of sclerochoroidal calcifications remains unclear but systemic conditions should be discarded. It is important to distinguish sclerochoroidal calcifications from other conditions such as tumors.


Resumo Calcificações esclerocoroidais (SC) são uma condição ocular rara e benigna caracterizada por lesões sub-retinianas irregulares amarelo-brancas, geralmente encontradas na arcada superotemporal do fundo médio-periférico em homens idosos de meia-idade. Apresentamos um caso clínico de uma paciente de 79 anos que durante exame de fundo apresentou nódulos esbranquiçados elevados na arcada superotemporal do olho direito. Após realizar tomografia de coerência óptica, ultra-sonografia, tomografia computadorizada ocular e análise laboratorial, ela foi diagnosticada com calcificações esclerocoroidais idiopáticas A patogênese das calcificações esclerocoroidais permanece incerta, mas as condições sistêmicas devem ser descartadas. É importante distinguir calcificações esclerocoroidais de outras condições, como tumores.


Subject(s)
Humans , Female , Aged , Calcinosis/diagnostic imaging , Scleral Diseases/diagnostic imaging , Choroid Diseases/diagnostic imaging , Tomography, X-Ray Computed/methods , Ultrasonography/methods , Clinical Laboratory Techniques/methods , Tomography, Optical Coherence/methods , Diagnosis, Differential , Metabolic Diseases
2.
Arq. bras. oftalmol ; 83(1): 19-27, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088958

ABSTRACT

ABSTRACT Purpose: To assess the reproducibility of retinal and choroidal measurements in the macular and peripapillary areas using swept-source optical coherence tomography in patients with Parkinson's disease. Methods: A total of 63 eyes of 63 patients with idiopathic Parkinson's disease were evaluated using a three-dimensional protocol of swept-source optical coherence tomography. The following layers were analyzed: full retinal thickness, retinal nerve fiber layer, ganglion cell layer, and choroid. The coefficient of variation was calculated for every measurement. Results: In the macular area, the mean coefficients of variation of retinal thickness, ganglion cell layer + thickness, and choroidal thickness were 0.40%, 0.84%, and 2.09%, respectively. Regarding the peripapillary area, the mean coefficient of variation of the retinal nerve fiber layer thickness was 2.78. The inferior quadrant showed the highest reproducibility (coefficient of variation= 1.62%), whereas the superonasal sector showed the lowest reproducibility (coefficient of variation= 8.76%). Conclusions: Swept-source optical coherence tomography provides highly reproducible measurements of retinal and choroidal thickness in both the macular and peripapillary areas. The reproducibility is higher in measurements of retinal thickness versus choroidal thickness.


RESUMO Objetivo: Avaliar a reprodutibilidade das medições da retina e da coroide nas áreas macular e peripapilar utilizando a tomografia de coerência ótica com fonte de varredura pacientes com doença de Parkinson. Métodos: Um total de 63 olhos de 63 pacientes com doença de Parkinson idiopática foram avaliados usando um protocolo 3D de tomografia de coerência ótica de fonte Triton Swept. Foram analisadas as seguintes camadas: espessura retiniana total, camada de fibras nervosas da retina, camada de células ganglionares e coróide. O coeficiente de variação foi calculado para cada medição. Resultados: Na área macular, os coeficientes médios de variação da espessura da retina, da camada de células ganglionares + espessura e da espessura da coróide foram de 0,40%, 0,84% e 2,09%, respectivamente. Em relação à área peripapilar, o coeficiente médio de variação da espessura da camada de fibras nervosas da retina foi de 2,78%. O quadrante inferior apresentou a maior reprodutibilidade (coeficiente de variação= 1,62%), enquanto o setor superonasal apresentou a menor reprodutibilidade (coeficiente de variação= 8,76%). Conclusões: A tomografia de coerência ótica de fonte Triton Swept fornece medições altamente reprodutíveis da espessura da retina e da coroide nas áreas macular e peripapilar. A reprodutibilidade é maior nas medidas da espessura da retina versus a espessura da coróide.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Parkinson Disease/complications , Retina/diagnostic imaging , Choroid Diseases/etiology , Choroid Diseases/diagnostic imaging , Choroid/diagnostic imaging , Retina/anatomy & histology , Retina/physiopathology , Reproducibility of Results , Choroid/anatomy & histology , Choroid/physiopathology , Tomography, Optical Coherence/methods
3.
Arq. bras. oftalmol ; 82(6): 522-527, Nov.-Dec. 2019. graf
Article in English | LILACS | ID: biblio-1038687

ABSTRACT

ABSTRACT A 26-year-old woman presented at 28 weeks gestation with hypertensive choroidopathy associated with pre-eclampsia. Fundus photography, fundus autofluorescence, spectral-domain optical coherence tomography (SD-OCT), fluorescein angiography, and indocyanine green angiography were performed in both eyes in the immediate postoperative period. SD-OCT images were obtained before delivery and during a 3-month follow-up. Fundus autofluorescence exhibited patchy hyper- and hypoautofluorescent lesions; fluorescein and indocyanine green angiography revealed areas of choroidal ischemia; and SD-OCT showed disorganization of the outer retinal layers and disruption of the ellipsoid zone. After her blood pressure was stabilized, progressive recovery of the outer retinal layer was monitored on SD-OCT.


RESUMO Uma mulher de 26 anos de idade, com 28 semanas de gestação apresentando coroidopatia hipertensiva associada à pré-eclâmpsia. Retinografia, autofluorescência, tomografia de coerência óptica de domínio espectral, angiofluoresceínografia e angiografia com indocianina verde foram realizadas em ambos os olhos no período pós-operatório imediato do parto. Imagens da tomografia de coerência óptica de domínio espectral foram obtidas antes do parto e durante o seguimento de 3 meses. A autofluorescência apresentou lesões heterogêneas hiper e hipoautofluorescentes, a angiofluoresceínografia e angiografia com indocianina verde revelaram áreas de isquemia de coroide, e a tomografia de coerência óptica de domínio espectral apresentou desorganização das camadas externas da retina e interrupção da zona elipsóide. Após a estabilização da pressão sanguínea, a recuperação progressiva da camada externa da retina foi monitorada pela tomografia de coerência óptica de domínio espectral.


Subject(s)
Humans , Female , Pregnancy , Adult , Pre-Eclampsia , Choroid Diseases/etiology , Choroid Diseases/diagnostic imaging , Hypertension/etiology , Hypertension/diagnostic imaging , Remission, Spontaneous , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Retinal Pigment Epithelium/pathology , Retinal Pigment Epithelium/diagnostic imaging
4.
Arq. bras. oftalmol ; 79(3): 200-201, graf
Article in English | LILACS | ID: lil-787326

ABSTRACT

ABSTRACT We present a case of silent polypoidal choroidal vasculopathy (PCV) in a patient with angioid streaks. PCV was detected during a routine ophthalmic examination and confirmed by fluorescein angiography, indocyanine green angiography, and optical coherence tomography. After 2 years of follow-up, the PCV remained silent without any complications. We report this rare coexistence and review literature on this topic.


RESUMO Nós apresentamos um relato de vasculopatia polipoidal de coroide (PCV) em paciente com estrias angióides. Vasculopatia polipoidal de coroide detectada em exame oftalmológico de rotina e confirmado por angiofluoresceinografia, angiografia com indocianina verde e tomografia de coerência óptica. Após 2 anos de seguimento a vasculopatia polipoidal de coroide permaneceu quiescente, sem qualquer complicação. Nós relatamos esta coexistência rara e apresentamos revisão da literatura.


Subject(s)
Humans , Female , Adult , Choroid Diseases/complications , Choroid/blood supply , Angioid Streaks/complications , Fluorescein Angiography , Choroid Diseases/diagnostic imaging , Choroid/diagnostic imaging , Tomography, Optical Coherence/methods , Fundus Oculi , Indocyanine Green , Angioid Streaks/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL